You should restart the computer after you install the OPC Core Components. You should configure DCOM as described in section 4. This error means that the current permissions are not enough to establish a connection.
Note: For more information about DVP-06XA, please refer the user manual and you can download the manual on Delta official.Print version OPC and DCOM Configuration on Windows 2008 and Windows 7 As a result, the D0 is set as analog input. The program means read data from analog module DVP-06XA to D0. The ladder program for example is as below: In theladder program (WPLSpft), you have to indicate the register to store the analog input data from 06XA. About the address, please refer the appendix.Ģ-14. Define the DI tag (Address = 001281, Data type = Boolean, Client Address = Read/Write) and then click Apply to apply the changes. About the address, please refer the appendix.Ģ-13. Click as indicated in the screen below, to add a static Tag for DI, DO, and AI,AO.Ģ-11.Define the DI tag (Address = 100065, Data type = Boolean, Client Address = Read only) and then click Apply to apply the changes.
After setting finished, click Finish.Ģ-10. Then do some custom settings, or you can just follow the default settings. Setup Modbus TCP port (502),select the IP Protocol as TCP/IP and then click Next.Ģ-9.
Define the EN01 IP and use default ID (0) in Device ID field. Select the device model (Modbus) and then click Next.Ģ-7. Add a new Device (Enter the name of the device) and then click Next.Ģ-6. After setting finished, click Finish.Ģ-5. Then you can do some custom settings of KEPServer EX, or you can just follow the default settings. Select the correct Network Adapter on your Host and then click Next.Ģ-4.
Select the Device driver (Modbus Ethernet) that you want to assign to the channel and then click Next.Ģ-3. Run the KEPServerEX OPC Server to add a new channel and then click Next.Ģ-2.
How to setup KEPServer EX communication with DVP28SV by EN01Ģ-1. Network setting –IP configuration (Static/DHCP), IP address, Netmask, Gateway.Ģ. The basic information of EN01, includes IP address, MACaddress, firmware version and so on. The configuration window will be pop out. Double click the module in the left window. If success, the result will be just like the broadcast.ġ-5. User can type IP address in the upper space. Press “IP search” button, then the input IP address window will pop out. If success, the left window will show all EN01 modules in thenetwork. Press “Broadcast” button, then WPLSoft will start to search EN01 in the network. Set “Ethernet ” as your communication port. Broadcast: If this is the first time you connectEN01 to Ethernet and have no idea what’s its IP address, then you can use “broadcast” to look for EN01 in the network.Ĭommunication setting” to set PLC communication port. There is two way to search EN01 via Ethernet.
:Configuring EN01 via RS-232.(Doesn’t need to connect to Ethernet) 1-4. :Looking for EN01 module via indicating IP address. :Looking for EN01 module via broadcasting. Plug EN01 to 28SV left side and plug 06XA toright side. How to connect DVP28SV, EN01 and 06XA.ġ-1. How to setup KEPServer EX communication with DVP28SV by RS-485ġ. How to setup KEPServer EX communication with DVP28SV by EN01 3. In this technical note, we cover the following topics. How to use KEPServer EX opc server with DVP28SV11R/T + DVPEN01-SL+DVP06XA